저독성 난연 저연 전선의 시험 방법

DC Field Value Language
dc.contributor.advisor이교범-
dc.contributor.author장만우-
dc.date.accessioned2019-10-21T07:23:34Z-
dc.date.available2019-10-21T07:23:34Z-
dc.date.issued2014-08-
dc.identifier.other17889-
dc.identifier.urihttps://dspace.ajou.ac.kr/handle/2018.oak/18484-
dc.description학위논문(석사)--아주대학교 IT융합대학원 :IT융합공학과,2014. 8-
dc.description.tableofcontents제1장 서론 1. 논문의 목적 2. 논문의 내용 제2장 이론적 배경 1. 저독성 난연 저연 전선에 대한 이해 2. 저독성 난연 저연 전선의 국내외 사용 현황 3. 저독성 난연 저연 전선의 시험 방법 제3장 시험 방법 1. 저독성 난연 저연 전선의 시험 환경의 구축 2. 저독성 난연 저연 전선의 시험 및 결과 제4장 결론 참고문헌 ABSTRACT-
dc.language.isokor-
dc.publisherThe Graduate School, Ajou University-
dc.rights아주대학교 논문은 저작권에 의해 보호받습니다.-
dc.title저독성 난연 저연 전선의 시험 방법-
dc.typeThesis-
dc.contributor.affiliation아주대학교 IT융합대학원-
dc.contributor.departmentIT융합대학원 IT융합공학과-
dc.date.awarded2014. 8-
dc.description.degreeMaster-
dc.identifier.localId652748-
dc.identifier.urlhttp://dcoll.ajou.ac.kr:9080/dcollection/jsp/common/DcLoOrgPer.jsp?sItemId=000000017889-
dc.subject.keyword저독성-
dc.description.alternativeAbstractThis paper presents the international standard of safety test for halogen free flame retardant low smoke electric wires. This is to verify that safety test standard should be applied in accordance with the intended use environment and purpose by performing safety tests for halogen free flame retardant low smoke electric wires. For this, domestic and international usage survey and safety test of halogen free flame retardant low smoke electric wires were conducted. The result shows that there is interest about halogen free flame retardant low smoke electric wires, and this is applied in the standard mentioned by the Electric Appliance Safety Control Act and Industrial Standardization Act in Korea. In addition, it is shown that the United States, Europe, China and Japan have different standards for halogen free flame retardant low smoke electric wires. How safety tests are conducted internationally and the different standards have been studied based on the results of domestic and international investigation. In addition, wire samples were analyzed under the same conditions. As a result, it is confirmed that safety tests should be applied in accordance with the intended use environment and purpose.-