슬관절 전치환술에서 3차원 단층촬영술을 이용한 슬개골의 가상 절제

DC Field Value Language
dc.contributor.advisor원예연-
dc.contributor.authorPark, Do Young-
dc.date.accessioned2019-10-21T07:19:11Z-
dc.date.available2019-10-21T07:19:11Z-
dc.date.issued2012-02-
dc.identifier.other12226-
dc.identifier.urihttps://dspace.ajou.ac.kr/handle/2018.oak/18116-
dc.description학위논문(석사)아주대학교 일반대학원 :의학과,2012. 2-
dc.description.abstractBackground: Though rotational alignment and antero-posterior positioning of the femoral component influences patello-femoral mechanics, it is also significantly influenced by the accuracy of the patellar resection, with the resultant thickness and symmetry of the patella-implant composite Methods: We performed virtual patellar resection with digital software using 3D-CT scans of knees from 49 patients who underwent primary TKR at our hospital, comparing two commonly used resection methods, i.e., the tendon method (TM), and the subchondral method (SCM), to determine an ideal resection plane with respect to the symmetry and thickness of the patellar remnant. Results: The TM gave a thicker resected patella, and a less oval cut surface shape which gives better coverage for a domed prosthesis. Both methods however, gave a symmetric resection both superio-inferiorly as well as medio-laterally. Conclusions: Though TM appears statistically better with respect to the thickness and cut surface shape, only further intra-operative studies with long-term clinical follow up may provide us with the most appropriate patellar resection method.-
dc.description.tableofcontentsTABLE OF CONTENTS ABSTRACT ⅰ TABLE OF CONTENTS iii LIST OF FIGURES iv LIST OF TABLES v Ⅰ. INTRODUCTION 1 Ⅱ. MATERIALS AND METHODS 3 A. MATERIALS 3 1. SUBJECTS 3 B. METHODS 5 1. SETTING 5 2. STATISTICS 11 III. RESULTS 12 IV. DISCUSSION 14 Ⅴ. CONCLUSION 20 REFERENCES 21 국문요약 25 LIST OF FIGURES Fig. 1. Reconstruction of 3-D CT images of the knee using specialized computer software 4 Fig. 2. Thickness of patella in the 3D image 6 Fig. 3. Subchondral method 7 Fig. 4. Anatomic landmarks chosen for resection at the fat fascia-tendon junctions for the tendon method of resection 8 Fig. 5. Measurement of ML symmetry and SI symmetry 10 Fig. 6. A schematic representation of the resection planes with the 2 methods 16-
dc.language.isoeng-
dc.publisherThe Graduate School, Ajou University-
dc.rights아주대학교 논문은 저작권에 의해 보호받습니다.-
dc.title슬관절 전치환술에서 3차원 단층촬영술을 이용한 슬개골의 가상 절제-
dc.title.alternativeDo Young Park-
dc.typeThesis-
dc.contributor.affiliation아주대학교 일반대학원-
dc.contributor.alternativeNameDo Young Park-
dc.contributor.department일반대학원 의학과-
dc.date.awarded2012. 2-
dc.description.degreeMaster-
dc.identifier.localId569839-
dc.identifier.urlhttp://dcoll.ajou.ac.kr:9080/dcollection/jsp/common/DcLoOrgPer.jsp?sItemId=000000012226-
dc.subject.keywordpatella-
dc.subject.keyword3D CT-
dc.subject.keywordpatellar resurfacing-
Appears in Collections:
Graduate School of Ajou University > Department of Medicine > 3. Theses(Master)
Files in This Item:
There are no files associated with this item.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse