백색광 간섭계를 이용한 안구 돌출 측정 장치

DC Field Value Language
dc.contributor.advisor김영길-
dc.contributor.author장중수-
dc.date.accessioned2019-08-13T16:41:15Z-
dc.date.available2019-08-13T16:41:15Z-
dc.date.issued2019-08-
dc.identifier.other29056-
dc.identifier.urihttps://dspace.ajou.ac.kr/handle/2018.oak/15568-
dc.description학위논문(박사)--아주대학교 일반대학원 :의용공학과정,2019. 8-
dc.description.tableofcontentsABSTRACT 1. Introduction 1 2. Related Studies 4 2.1. Exophthalmos 4 2.1.1. Exophthalmos 4 2.1.2. Thyroid ophthalmopathy 5 2.2. WSI(White light Scanning Interferometer) 9 3. Existing manual exophthalmometer 12 3.1. Types and principles of manual exophthalmometers 12 3.1.1. Hertel exophthalmometer 12 3.1.2. Naugle exophthalmometer 14 3.2. Reproducibility of manual exophthalmometers 17 4. Proposed a System for Exophthalmos Measurement using a WSI 19 4.1. System overview 19 4.2. System Configuration 20 4.2.1. Measuring unit 20 4.2.2. Mechanical unit 25 4.2.3. Electric unit 27 4.2.4. Control unit 28 5. Experiment and Result and Analysis 30 5.1. Experiment Method 30 5.2. Experiment Results and Analysis 36 6. Conclusion 65 REFERENCE ABSTRACT (Korean)-
dc.language.isoeng-
dc.publisherThe Graduate School, Ajou University-
dc.rights아주대학교 논문은 저작권에 의해 보호받습니다.-
dc.title백색광 간섭계를 이용한 안구 돌출 측정 장치-
dc.title.alternativeChang jung soo-
dc.typeThesis-
dc.contributor.affiliation아주대학교 일반대학원-
dc.contributor.alternativeNameChang jung soo-
dc.contributor.department일반대학원 의용공학과정-
dc.date.awarded2019. 8-
dc.description.degreeDoctoral-
dc.identifier.localId951973-
dc.identifier.uciI804:41038-000000029056-
dc.identifier.urlhttp://dcoll.ajou.ac.kr:9080/dcollection/common/orgView/000000029056-
dc.description.alternativeAbstractThe relative position of the orbital eye can be a criterion for evaluating several pathological conditions. It is especially useful to diagnose orbital fractures, thyroid eye disease, orbital tumors and to evaluate the outcome of medication and surgical treatment. Hertel and Naugle are representative measurement tools used to measure exophthalmometic values, and have different measurement results, such as fixed orbits, every time they are inspected, even if the same inspector repeatedly measures them. Even with the same calibrator, it is inevitable that different manufacturers will change the design of the stationary part of the orbit, causing the surveyor to make a measurement error. In order to improve the error of the conventional manual protrusion system, we designed and manufactured an automatic protrusion measuring system using a white light interferometer, which has already been used in the inspection and measurement fields of the semiconductor and display industries. And to show better measurement reproducibility. The degree of protrusion of the eyeball was measured 50 times using a system proposed by one subject in 44 eyes of 22 subjects. The error of measurement of the orbital projection using the proposed system is ±0.041㎜, which is more reproducible than the error of ±1.0-1.5㎜ of the conventional manual orbital system. Diagnosis of orbital fracture, thyroid eye disease, orbital tumor, And to evaluate the outcome of surgical treatment.-
Appears in Collections:
ETC > ETC
Files in This Item:
There are no files associated with this item.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse