Dead-Beat 제어를 이용한 단상 비엔나 정류기의 전류 품질 향상 방법
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | 이교범 | - |
dc.contributor.author | 권용대 | - |
dc.date.accessioned | 2018-11-08T08:28:46Z | - |
dc.date.available | 2018-11-08T08:28:46Z | - |
dc.date.issued | 2018-08 | - |
dc.identifier.other | 27836 | - |
dc.identifier.uri | https://dspace.ajou.ac.kr/handle/2018.oak/14170 | - |
dc.description | 학위논문(석사)--아주대학교 일반대학원 :전자공학과,2018. 8 | - |
dc.description.tableofcontents | CHAPTER I. INTRODUCTION CHAPTER II. CONVENTIONAL CONTROL METHOD 2.1 Structure of the Vienna Rectifier 2.2 Vienna Rectifier with applying a Conventional PI Controller CHAPTER III. PROPOSED CONTROL METHOD 3.1 Calculation of The Slope of Inductor Current 3.2 Calculation of Optimal Duty cycle of CCM 3.3 Calculation of Optimal Duty cycle of DCM 3.4 Mode Verifying Algorithm CHAPTER IV. SIMULATIONS 4.1 Simulation Results CHAPTER V. EXPERIMENTS CHAPTER VI. CONCLUSIONS REFERENCES | - |
dc.language.iso | eng | - |
dc.publisher | The Graduate School, Ajou University | - |
dc.rights | 아주대학교 논문은 저작권에 의해 보호받습니다. | - |
dc.title | Dead-Beat 제어를 이용한 단상 비엔나 정류기의 전류 품질 향상 방법 | - |
dc.title.alternative | Quality Improvement of Line Current for Single-phase Vienna Rectifiers Using a Dead-Beat Controller | - |
dc.type | Thesis | - |
dc.contributor.affiliation | 아주대학교 일반대학원 | - |
dc.contributor.department | 일반대학원 전자공학과 | - |
dc.date.awarded | 2018. 8 | - |
dc.description.degree | Master | - |
dc.identifier.localId | 887739 | - |
dc.identifier.uci | I804:41038-000000027836 | - |
dc.identifier.url | http://dcoll.ajou.ac.kr:9080/dcollection/common/orgView/000000027836 | - |
dc.subject.keyword | 계통연계 | - |
dc.subject.keyword | 제어기 설계 | - |
dc.subject.keyword | 컨버터 | - |
dc.subject.keyword | 비엔나 정류기 | - |
dc.subject.keyword | 단상 PFC | - |
dc.description.alternativeAbstract | This paper proposes a dead-beat control method for the improving the line current quality of single-phase Vienna rectifier. Proportional-integral (PI) controllers are adopted to the conventional single-phase Vienna rectifiers to alleviate its line current. The PI controller is appropriate for controlling DC components. The dynamic characteristics of PI controller is not fast enough to following the reference current in the regions near at the line current’s zero-crossing section which has an AC component. Thus, increment of the total harmonic distortion (THD) occurs due to the degeneration of the power factor (PF). In order to solve this problem, a controller with a fast dynamic response is required. The dead-beat controller which has the fast dynamics is applied as the solution to improve the line current quality. In addition to this method, a current mode verifying method is also applied, in order to control the average current both in the continuous current mode (CCM) and the discontinuous current mode (DCM) region. Moreover, by predicting the next current state, the optimal duty cycle of the single-phase Vienna rectifier can be calculated. Applying the proposed method to the single- phase Vienna rectifier, the quality of the line current is improved, and the PF is controlled to the unity. The validity verifying of the detail operation of proposed DBC algorithm is deducted by using a PSIM simulation and an experiment with single-phase Vienna rectifier prototype. | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.