통합운영 자동화 S/W 개발 및 적용방안 연구

DC Field Value Language
dc.contributor.advisor이교범-
dc.contributor.author양지아-
dc.date.accessioned2018-11-08T08:12:28Z-
dc.date.available2018-11-08T08:12:28Z-
dc.date.issued2014-02-
dc.identifier.other16291-
dc.identifier.urihttps://dspace.ajou.ac.kr/handle/2018.oak/11687-
dc.description학위논문(석사)--아주대학교 산업대학원 :정보전자공학과,2014. 2-
dc.description.tableofcontents제 1 장 서론 10 제 2 장 수처리공정 시설개요 12 2.1 수처리공정 시설개요 12 2.2 수처리공정 자동화 목표수준 16 2.3 수처리공정 자동화 운영수준 18 제 3 장 소독공정 자동운전 19 3.1 소독공정 설비개요 19 3.2 소독공정 자동운전의 문제점 23 3.3 감시제어설비 소프트웨어의 한계 25 제 4 장 제어로직 어플리케이션 개발 27 4.1 제어로직 어플리케이션 개발 27 4.2 염소주입설비 개선 30 4.3 제어로직 어플리케이션 개선 31 4.4 운영결과 분석 34 제 5 장 결론 39 참고문헌 41-
dc.language.isokor-
dc.publisherThe Graduate School, Ajou University-
dc.rights아주대학교 논문은 저작권에 의해 보호받습니다.-
dc.title통합운영 자동화 S/W 개발 및 적용방안 연구-
dc.typeThesis-
dc.contributor.affiliation아주대학교 산업대학원-
dc.contributor.department산업대학원 정보전자공학과-
dc.date.awarded2014. 2-
dc.description.degreeMaster-
dc.identifier.localId608879-
dc.identifier.urlhttp://dcoll.ajou.ac.kr:9080/dcollection/jsp/common/DcLoOrgPer.jsp?sItemId=000000016291-
dc.subject.keyword자동화-
dc.subject.keywordS/W-
dc.description.alternativeAbstractThe goal of this paper is to contribute to cost reduction and the securing of stable water quality at the outflow point of the clear water reservoir by proposing a feedback control which analyzes the problem of the feedback control system utilized in the past and automatically considers the residence time with the purpose of overcoming the limit of manual operation according to a chart of data During the disinfection process of water treatment plants in K-water, the operation workers mostly determine the chlorine injection rate with manual operation based on the chart to inject chlorine. Also, the feedback control system utilized in the past, operating with fixed residence time, showed the limit of automatic operation because it was unable to appropriately respond to the change of water filtration quantities, which resulted in exceeding standard for the K-water water quality Accordingly, proposing a disinfection process control system that automatically calculates the residence time from water filtration quantities, after comparing the data from injection rate operation, it has been verified that there is more than 1.5 Times improvement in direction of the target outflow concentration.-